Difference between revisions of "Edge Configuration"

From AMTech WikiDocs
Jump to: navigation, search
(Configuration validation)
Line 61: Line 61:
 
* "bridgeId":"m2mCreator:m2mBridge", '''the name of the M2MBridge instance'''
 
* "bridgeId":"m2mCreator:m2mBridge", '''the name of the M2MBridge instance'''
 
==Configuration validation==
 
==Configuration validation==
 +
*At startup time the M2MBridge validates it configuration with the cloud is an error occurrences the application aborts
 +
*To simplify the process of validation configuration there is an option at Sensor network to [[Sensor%27s_network#Observation_production_.26_M2MBridge_validation|validate]] a configuration for a M2MBridge instance

Revision as of 21:54, 2 June 2016

Edge

There are 2 types of M2MBridge configurations:

1 Clone configuration, from a M2MBridge instance references as “template” it clones the configuration

  • The objectives is from one configuration create and maintain multiples deployments, it requires template id and prefix to be defined in the bridgeConfig.json

2 Instance configuration, from an existing M2MBridge instance references as bridgeId it requires bridgeId to be defined in the bridgeConfig.json

Example of Clone Configuration

bridgeConfig.json located at M2MBridge.js directory

{
    "description": "AMTech M2M Bridge", 
    "description:children" : true,
    "dap":{   
        "dapUrl": "https://dap.amtech.mx",     
        "userId": "xxxxxxx@amtech.mx",
        "tenant" : "xxxxxxx",  
        "password" :"xxxxxxxx"
    },
    "templateId":"m2mCreator:m2mBridge",
    "bridgeIdPrefix":"tienda1",       
    "location": "{\"wkt\":\"POINT(-99.17125583 19.40501031)\",\"sContext\":\"geo\"}",  
    "location:children" : true,
    "address" :{				 
        "country" : "usa",
        "city": "Las Vegas",
        "road": "Las Vegas Boulevard South",
        "number":"3960"
    },
}
  • "description": "AMTech M2M Bridge" Text to be assigned to M2MBridges description property
  • "description:children" : true If the description property will be assigned to M2MBridge's linked things
  • "dapUrl": "https://dap.amtech.mx" Amtech IoT DAP url
  • "userId": "xxxxxxx@amtech.mx" m2mBridge instance user id
  • "tenant" : "xxxxxxx", bridge tenant
  • "password" :"xxxxxxxx" m2mBridge password
  • "templateId":"m2mCreator:m2mBridge" M2MBridge instance id to be cloned
  • "bridgeIdPrefix":"tienda1", Prefix to add to the unique M2MBridge identifier, the mac address of the device is use as unique id, In absence of the prefix just the mac address is used as identifier
  • "location": "{\"wkt\":\"POINT(-99.17125583 19.40501031)\",\"sContext\":\"geo\"}" wkt location to set m2mBridge location overrides address
  • "location:children" : true, if the location property will be assigned to M2MBridge's linked things
  • "address" Address to be used to get m2mBridge's location

Example of Instance configuration

{
    "description": "AMTech M2M Bridge", 
    "dap":{   
        "dapUrl": "https://dap.amtech.mx",     
        "userId": "xxxxxxx@amtech.mx",
        "tenant" : "xxxxxxx",  
        "password" :"xxxxxxxx"
    },
    "bridgeId":"m2mCreator:m2mBridge",
    "location": "{\"wkt\":\"POINT(-99.17125583 19.40501031)\",\"sContext\":\"geo\"}",  
    "address" :{				 
        "country" : "usa",
        "city": "Las Vegas",
        "road": "Las Vegas Boulevard South",
        "number":"3960"
    },
}
  • "bridgeId":"m2mCreator:m2mBridge", the name of the M2MBridge instance

Configuration validation

  • At startup time the M2MBridge validates it configuration with the cloud is an error occurrences the application aborts
  • To simplify the process of validation configuration there is an option at Sensor network to validate a configuration for a M2MBridge instance